Rotary Calciner
Calcining is heating the material to a certain temp. for certain time and for a particular operation.
Often calcining process for organic materials produces hazardous gases which cannot be left to atmosphere.
Many times these gases have heating value and hence they are recirculated through a combustion chamber for heat recovery.
Indirect calciner
Products pass through a tube ,which is heated from outside , both , products of combustion and liberated gases are sucked by pollution control equipment to make them dischargeable In this system calcination under atmospheric control is possible.
Heating media can be electrical gas oil fired.
Direct fired
Material and combustion devices are normally in the same side as a concurrent system some time counter current .
Both products of combustion and gases are treated in pollution control system.
- Waste disposal management is essential for any enterprise.
- Through in-house R&D, and proficiency in combustion engineering, Dhanaprakash Industrial Corporation have developed waste disposal systems for waste disposal management applications, including hazardous industrial, chemical and bio-medical waste.
- Solid wastes are recommended to be calcined- rotary calciner is recommended for many applications.
Down Draft Incinerator
- Down draft incinerator with pollution control device.
- Gas quencher, Ventury scrubber, Mist separator, ID fan, Solid, Liquid, Gaseous feeds accepted.
- Emissions as per Indian and International Pollution control norms.
- Residue in glass state.
- Maximum temperature 1050ºC.
- Fully automatic operation.
- Fuel - Diesel, Natural Gas.
Bio Medical Waste Incinerator
- Bio medical waste incinerators are recommended for elimination of hazardous bio medical wastes.
- MW as per rules revised in 2016- 10Kg to 250 Kg per hour.
MPCB APPROVED
- Waste disposal management is essential for any enterprise.
- Through in-house R&D, and proficiency in combustion engineering, Dhanaprakash Industrial Corporation have developed waste disposal systems for waste disposal management applications, including hazardous industrial, chemical and bio-medical waste.
- Bio medical waste incinerators are recommended for elimination of hazardous bio medical wastes.
- BMW as per rules 1998- 10Kg to 100 Kg per hour.
Hazardous Waste Incinerator
- Down draft incinerator with pollution control device.
- Gas quencher, Ventury scrubber, Mist separator,ID fan, Solid, Liquid, Gaseous feeds accepted.
- Emissions as per Indian Pollution control norms.
- Residue in glass state.
- Maximum temperature 1050ºC.
- Fully automatic operation.
- Fuel - furnace oil, LDO, Diesel, Natural Gas.
Downnload Brochures
Calciner